Service \ Assembly & integration \ Surface treatment & functionalization
SURFACE TREATMENT & FUNCTIONALIZATION
Wettability control and biomolecule immobilization on plastics, glass, silicon, PDMS and particles.
MATERIAL
Plastics · glass · silicon · PDMS · particles
MINIMUM ORDER
No strict minimum
LEAD TIME
Quoted with the device
\ OVERVIEW
Surface treatment & functionalization
Surface functionalization modifies the wettability, adhesion and binding characteristics of a device surface to suit the assay. At microfluidic dimensions the surface-area-to-volume ratio is high enough that these properties decide whether a chip fills, whether cells attach, and whether an analyte is captured. We run hydrophilic and hydrophobic treatments, patterned wettability, automated microarray spotting and covalent biomolecule immobilization on polystyrene, PMMA, COC/COP, glass, silicon, PDMS and particles. The substrate decides the route as much as the target does: the same contact angle on polystyrene and on glass takes two routes.


< 10°
hydrophilic contact angle

110–150°
hydrophobic contact angle

11 × 4
surface functions across four methods

5
substrate classes — plastics, glass, silicon, PDMS, particles

ISO 13485
certified · FDA registered
\ CAPABILITIES
Capabilities and technical specifications
Four methods under one roof — plasma, wet chemical, spin coating and thin-film deposition — so the route is chosen for the function and the substrate. Contact angle is the acceptance criterion on every wettability treatment, and the sequence relative to bonding is fixed at DFM.
Capability matrix — surface function by method
The matrix is our actual routing; the contact angle we commit to is stated per substrate in the quotation.
● offered by this method ○ not the route we use for this function.
SURFACE FUNCTION
PLASMA
WET CHEMICAL
SPIN COATING
THIN FILM CVD/PVD
TYPICAL APPLICATIONS
Hydrophilic
●
●
●
●
Capillary filling, rapid wetting, bubble reduction, sample loading
Hydrophobic
○
●
●
●
Hydrophobic valves, aqueous-phase isolation, droplet manipulation, digital microfluidics
Fluorophilic / oil-wetting
○
●
○
○
Water-in-oil droplets, digital PCR, single-cell droplets, double emulsions
Tissue culture
●
○
○
○
Adherent-cell culture, cell counting, cytotoxicity, organ-on-chip surfaces
ECM / bioactive
○
●
○
○
Collagen, fibronectin or laminin; cell migration, vascularization models
Ultra-low attachment
○
●
○
●
Spheroids, organoids, embryoid bodies, suspension culture
Low protein-binding
○
●
○
○
Immunoassays, protein detection, blood samples, biosensors
Biomolecule immobilization
○
●
○
●
Antibodies, DNA, aptamers, enzymes, peptides
Electrode surface
○
○
●
●
Electrochemical biosensors, impedance, MEA, EWOD, microheaters, DEP
Dielectric / passivation
○
○
●
●
EWOD dielectric layers, electrode insulation, capacitive sensing
Selective / patterned
○
○
●
●
Local wettability regions, cell patterning, multiplexed assay zones
Achievable wettability
Capability is the best achievable under the optimum method and substrate; delivered is what we measured on shipped devices.
CAPABILITY
DELIVERED RESULT
Hydrophilic
Contact angle below 10° — plasma, chemical grafting, silanization, CVD or polymer coupling
Below 60° measured on polystyrene and PMMA devices
Hydrophobic
Contact angle 110–150° — functional coatings, chemical modification or bioinspired micro-nano patterning
Above 105° measured on glass
Patterned
Blanket or selective — hydrophilic and hydrophobic regions on one surface
Below 60° and above 105° on one patterned silicon part
Immobilization
Covalent attachment of antibodies, DNA, aptamers, enzymes and peptides
Selective in-well functional groups with a hydrophobic exterior, on silicon
Microarray spotting and embedding
Spotting
Automated microarray spotting with position recognition, eliminating manual placement error
Repeatability
Consistent coating across a batch; batch-to-batch variability controlled by process rather than operator
Channel surface modification
Covalent immobilization of biomolecules such as antibodies onto solid-phase substrates, for the specificity, signal reliability and reproducibility that diagnostic and analytical systems need
Production
Batch production; spotting runs where the design uses arrays
Functionalize after bonding, not before.
Fusion and diffusion bonding run near the glass transition and destroy pre-applied surface chemistry — proteins denature and functional groups are lost. Either functionalize after the device is sealed, or choose a lower-temperature bonding method: solvent, adhesive or PSA. This is a design-stage decision; discovering it at first article normally means remaking the part.
Equipment
Four methods need four sets of tooling. Most contract manufacturers hold one route — usually plasma — and subcontract or decline the rest.

Plasma system — the hydrophilic and tissue-culture routes

CVD/PVD — electrode surfaces, passivation and conformal coating

Wet chemical bench — immobilization, ECM, ultra-low attachment and low protein-binding

Parylene coater — conformal coating over particles and our own porous membranes

Spin coater — blanket films: electrode surfaces, dielectric passivation, patterned layers

Microarray spotter — repeatability across batches without operator placement
\ MATERIALS
Materials
A house that only treats polystyrene has one recipe, not a capability. Here is what we have delivered, class by class.

Thermoplastics Polystyrene · PMMA · COC · COP
DELIVERED TREATMENTS
Hydrophilic (PS, PMMA) · tissue culture (PS, COC/COP)
NOTE:
Hydrophilic treatment measured below 60° on PS and PMMA; the same contact angle on polystyrene and on glass takes two different routes

Rigid inorganic Borosilicate glass · silicon
DELIVERED TREATMENTS
Hydrophobic (glass) · tissue culture (glass) · patterned hydrophilic + hydrophobic (silicon) · selective in-well immobilization (silicon)
NOTE:
Hydrophobic glass above 105°; both regions measured on one patterned silicon part

Elastomer PDMS
DELIVERED TREATMENTS
Plasma activation
NOTE:
Begins reverting within about fifteen minutes unless thermally aged — bond or use promptly

Particles Magnetic and other particulate substrates
DELIVERED TREATMENTS
Conformal Parylene coating
NOTE:
Passivation for chemical stability and biocompatibility; the same coater covers our own porous membranes
Plasma vs. wet chemical vs. thin film
The method behind a function decides what the treatment is made of, how long it lasts and whether it can be patterned. Grade-level substrate data is in the Materials guide.
ASPECT
PLASMA
WET CHEMICAL
SPIN COATING · THIN FILM CVD/PVD
Functions on the matrix
Hydrophilic, tissue culture
Hydrophilic, hydrophobic, fluorophilic, ECM, ultra-low attachment, low protein-binding, immobilization
Hydrophilic, hydrophobic, ultra-low attachment, immobilization, electrode, dielectric, selective / patterned
What is on the surface
Activated groups on the polymer itself — nothing added
Grafted or coupled chemistry — silanes, polymers, proteins
A deposited film — metal, dielectric, Parylene or a spun polymer
Patterning
Blanket
Selective within a part — in-well chemistry with a passivated exterior
Blanket or patterned — local wettability regions, cell patterning, multiplexed zones
Durability
Shortest — plasma-activated PDMS begins reverting within about fifteen minutes unless thermally aged
Considerably more durable than plasma
Considerably more durable than plasma
\ PROCESS
Treatment process
Two wettability routes, set by the function and the substrate, then steps common to both: patterning, immobilization and measurement.
-
Route A — Hydrophilic
For capillary-driven filling, rapid wetting, bubble reduction and sample loading.

Function and substrate
The target surface behavior, the substrate, and what the surface must survive — sterilization, storage, solvent exposure.
Free DFM review

Method selection
Plasma treatment, chemical grafting, surface silanization, CVD or polymer coupling — chosen from the matrix against the substrate. Where bonding is involved, the sequence is fixed here.
5 hydrophilic routes

Treatment
Parameters developed on your actual substrate, not a coupon of something similar; then batch treatment with in-process checks.
< 10° capability · < 60° delivered on PS and PMMA
-
Route B — Hydrophobic
For hydrophobic valves, aqueous-phase isolation, droplet manipulation and digital microfluidics.

Function and substrate
The target behavior, the substrate, and what the surface must survive; whether the region is blanket or a valve, a well edge or a droplet zone.
Free DFM review

Method selection
Functional coatings, chemical modification or bioinspired micro-nano patterning — wet chemical, spin coating or thin film; plasma is not the route for this function.
3 hydrophobic routes

Treatment
Parameters developed on the actual substrate, then batch treatment with in-process checks.
110–150° capability · > 105° delivered on glass
-
Patterning, immobilization and measurement — common to both routes

Patterning and selective treatment
Hydrophilic and hydrophobic regions on one surface by spin coating and thin-film routes — local wettability regions, cell patterning, multiplexed assay zones. Wet chemistry for selective treatment inside a microwell, with a passivated exterior.
Both regions measured on one silicon part

Biomolecule immobilization and spotting
Covalent immobilization of antibodies, DNA, aptamers, enzymes or peptides; automated microarray spotting with position recognition where the design uses arrays.
Position-recognized, no manual placement

Contact-angle QC and release
Contact angle measured on treated parts as the primary acceptance criterion; uniformity mapped across the treated area where required; report format agreed at quotation.
Contact angle on every lot
The sequence rule.
Where the device is bonded, the treatment goes on after bonding — fusion and diffusion bonding run near the glass transition and would destroy chemistry applied before them, so the sequence is set by process compatibility. Treatment before closure is the exception, reserved for designs that close with a low-temperature method — solvent, adhesive or PSA. That is how our assembly lines run: hydrophilic treatment in line, before reagent loading and PSA bonding. The sequence is fixed at DFM.

\ QUALITY CONTROL
Quality control
Contact angle
Measured on treated parts; the primary acceptance criterion for wettability treatments
Spotting repeatability
Automated position recognition, with batch-to-batch variability controlled by process rather than operator
Durability and shelf life
Per treatment and substrate: how long it holds, under what storage, shelf life as supplied
Quality system
ISO 13485 certified · FDA registered
Coating uniformity
Mapped across the treated area where the application requires it
Delivered results
Below 60° on polystyrene and PMMA; above 105° on glass; both on one patterned silicon part
Data supplied
Contact-angle report and, where mapped, uniformity data — report format agreed at quotation stage
\ LEAD TIME & MOQ
Lead time & MOQ

Typically quoted
With the device it belongs to, rather than as a separate line

Sequence
After bonding where the device is bonded; before closure only where a low-temperature method — solvent, adhesive or PSA — closes it. Fixed at DFM

As a standalone service
We accept parts made elsewhere; terms follow the substrate process and are quoted per project

Indicative pricing
Quoted with the device

Minimum order
No strict minimum
\ SHOWCASE
Showcase
Sample parts
Seven delivered treatments across six substrates and four treatment classes. The list spans rigid and soft substrates, plastics and inorganics, blanket and patterned application, wettability control and covalent chemistry.
#
TREATMENT
MATERIAL
PATTERNING
MEASURED
APPLICATION
1
Hydrophilic
Polystyrene
Non-patterned
Contact angle < 60°
Capillary-driven chips for cell staining
2
Hydrophilic
Polystyrene
Non-patterned
Contact angle < 60°
Rapid chamber filling and uniform cell distribution for cell counting
3
Hydrophobic
Glass
Non-patterned, uniform
Water contact angle > 105°
Through-glass via (TGV) devices
4
Hydrophilic + hydrophobic
Silicon
Patterned
< 60° / > 105°
Wettability-patterned array chips
5
Tissue culture
PS, COC/COP, glass
Non-patterned, uniform
—
Cell-culture plates for adherent attachment and growth
6
Parylene coating
Magnetic particles
Conformal, uniform
—
Passivation of magnetic particles — chemical stability and biocompatibility
7
Selective hydrophobic + immobilized functional groups
Silicon
Microwell array — hydrophobic outside, functional groups inside
—
Microwell-array chips for sequencing: localized in-well capture, minimal non-specific binding

CASE 4
patterned silicon, both regions measured: below 60° and above 105°. Water beads on the hydrophobic regions and wets the hydrophilic ones.

Case 7
in-well chemistry with a passivated hydrophobic exterior: patterning, immobilization and passivation in a single part, the hardest one in the set.
Applications
CAPILLARY FILLING
Hydrophilic channels that fill by capillary action — pumpless cartridges that load a sample without an instrument.
TISSUE CULTURE · ULA
Tissue-culture surfaces for adherent growth; ultra-low-attachment surfaces for spheroids and organoids.
IN-WELL IMMOBILIZATION
Microwell arrays with capture chemistry inside the well and a hydrophobic exterior — localized capture, minimal non-specific binding.
FLUOROPHILIC
Oil-wetting channel walls for water-in-oil droplets, digital PCR, single-cell droplets and double emulsions.