Service \ Assembly & integration \ Reagent storage & lyophilization
REAGENT STORAGE & LYOPHILIZATION
On-board reagent storage — blisters, capsules, lyophilized beads and in-situ drying — loaded on our own lines.
MATERIAL
Blister · capsule · lyophilized bead · in-situ
MINIMUM ORDER
No strict minimum
LEAD TIME
3–4 weeks from agreed requirements
\ OVERVIEW
Reagent storage & lyophilization
Getting reagent into a microfluidic device and keeping it stable there is a separate engineering problem from making the device. Four formats cover it. For liquid: blisters and capsules — each a reservoir or chamber inside the cartridge, sized to the reagent volume and the release mechanism. For dry: lyophilized beads, metered and placed as discrete units, and in-situ lyophilization, where the reagent is dispensed into the device cavity and dried in place. All four are loaded on our own assembly lines, before closure; standalone beads also ship in customized storage tubes.


4 formats
blister · capsule · bead · in-situ

No cold chain
the point of drying the reagent

No strict MOQ
pricing improves with batch size

3–4 weeks
from agreed requirements

ISO 13485
certified · FDA registered
\ CAPABILITIES
Capabilities and technical specifications
Reagents are loaded on the line that builds the device — treatment before closure, reagent verified before it is sealed in. Your formulation stays yours; we build the storage around it.
Blister LIQUID STORAGE
Liquid reagent sealed in the cartridge until the device calls for it — sized to the reagent volume and the release mechanism.
Blister
Formed cavity under a foil-laminate lid; burst at a designed weak point. Fixed dose, defined actuation stroke.
Capsule
Chamber inside the cartridge; pierced, crushed or opened on actuation. Larger volumes, release sequences a blister cannot give.
Liquid storage tube
Dedicated tube customized to the volume and to how the chip uses it.
Choose it when the device is still changing.
Lyophilization DRIED STORAGE · NO COLD CHAIN
LYOPHILIZED BEAD
IN-SITU LYOPHILIZATION
How
Metered as a droplet, frozen as a sphere and dried — then each bead is checked and placed before closure
Dispensed into the device cavity as liquid and dried there, on the part
Equipment
Micro dispenser (droplet) · production lyophilizer · bead detection & placement
Micro dispenser (into the cavity) · production lyophilizer, device trays on the shelf
Approx. spec
Small, repeatable doses · dose fixed before drying
Larger dried volumes · cake takes the cavity's shape
Choose when
The cavity can accept and retain a bead; a bad unit must cost only a bead
A bead will not fit or reach, or would move in transit
Lyophilization · cavity treatment before loading
Sets how the reagent wets the cavity and reconstitutes — four methods, done on the line before dispensing
Sets how the reagent wets the cavity and reconstitutes — four methods, done on the line before dispensing
Full method and contact-angle detail: Surface treatment & functionalization →
Plasma
PLASMA SYSTEM
Activates the polymer surface — nothing added. Blanket treatment.
Hydrophilic < 10° · short-lived on PDMS (~15 min unless aged)
Wet chemical
WET CHEMICAL BENCH
Grafted or coupled chemistry — silanes, polymers, proteins. Selective within a part (in-well).
Hydrophilic or hydrophobic · durable
Spin coating
SPIN COATER
A spun polymer film over the surface, blanket or patterned.
Uniform film · durable
Thin film
CVD / PVD · PARYLENE COATER
A deposited film — metal, dielectric or Parylene; blanket, patterned or conformal.
Hydrophobic up to 110–150° · durable
Spec Dose, residual-moisture and shelf-life figures are agreed per formulation at DFM.
STORAGE & LOADING
Customization
Cavity, blister, capsule and tube geometry designed to the reagent volume and to how the chip uses it
Blister lidding
Foil laminate — the moisture and oxygen barrier that usually limits the shelf-life claim
Contact materials
PP, PE, COC/COP — low extractables, low sorption of the analyte or label
Closure
PSA lamination or film seal; seal integrity through shipping, temperature cycling and actuation
Loading
Filling, bead detection and placement on our assembly lines, before device closure
DRYING & RELEASE
Cycle development
Freeze, primary-dry and secondary-dry cycle built around your formulation, below its collapse temperature
Residual moisture
Specified as a window, agreed at DFM — Karl Fischer or loss on drying
Release tests
Residual moisture · reconstitution time · activity against your assay
Packaging
Reagent tubes with optional desiccant; moisture-barrier packaging for loaded devices
Quality system
ISO 13485 certified · FDA registered

\ PROCESS
Reagent loading process
Two ways to dry, chosen by the cavity; one closure and packaging line for everything.
-
Lyophilization — bead and in-situ

Requirements
Formulation, volume, release mechanism and acceptance criteria; drying cycle built below collapse temperature.
Below collapse temperature

Dispense
Micro dispenser meters a droplet (bead) or fills the device cavity (in-situ).
Dose fixed here

Freeze & dry
Frozen, then primary and secondary drying under vacuum to the residual-moisture target.
Residual-moisture target

Inspect (QC)
Every bead detected before placement; in-cavity cake checked; seals inspected; 100% vision.
Rejected, not sealed in

Closure & sealing
PSA lamination or film seal, without the dried reagent seeing ambient humidity.
No ambient exposure

Package & hand over
Tubes with optional desiccant, or barrier-packed devices; released to your stability study.
Foil laminate · desiccant
-
Blisters and capsules — fill and seal
The liquid formats take a shorter route, on the same line and in the same sequence relative to treatment and closure.

Requirement
Reagent volume, release mechanism, actuation force and contact-material constraints.
Below collapse temperature

Format and geometry
Blister cavity or capsule chamber designed against the cartridge interface, not selected from a catalog.
Dose fixed before drying

Tooling and samples
Cavity tooled and sampled for fit, fill, seal and releas
Freezing rate sets pore structure

Fill and seal
Dosed and sealed on the line, before device closure.
Residual-moisture target

Integration
Assembled into the device and inspected.
Detected before placed
Lead time
3–4 weeks
from agreed requirements
Cycle development
for a new formulation — ahead of the clock, quoted separately
No strict minimum
pricing improves with batch size
Two delivery forms
beads in reagent tubes, or loaded in the device
\ SHOWCASE
Showcase
Sample parts
The formats, photographed on parts made here.

Reagent storage blisters
liquid held against a burstable foil seal, released by a designed actuation stroke

Reagent capsule
a sealed reservoir inside the cartridge, isolated from the device until the moment of use

Lyophilized beads
metered, dried and checked before the device is involved, then placed robotically, or shipped standalone in dedicated reagent tubes

Reagent storage tube
Internal cavity geometry matches the reagent form for stable containment.