Service \ Assembly & integration \ Reagent storage & lyophilization

REAGENT STORAGE & LYOPHILIZATION

On-board reagent storage — blisters, capsules, lyophilized beads and in-situ drying — loaded on our own lines.

MATERIAL

Blister · capsule · lyophilized bead · in-situ

MINIMUM ORDER

No strict minimum

LEAD TIME

3–4 weeks from agreed requirements

\ OVERVIEW

Reagent storage & lyophilization

Getting reagent into a microfluidic device and keeping it stable there is a separate engineering problem from making the device. Four formats cover it. For liquid: blisters and capsules — each a reservoir or chamber inside the cartridge, sized to the reagent volume and the release mechanism. For dry: lyophilized beads, metered and placed as discrete units, and in-situ lyophilization, where the reagent is dispensed into the device cavity and dried in place. All four are loaded on our own assembly lines, before closure; standalone beads also ship in customized storage tubes.

Fluid sac 03.jpg
v19_01_four_formats_transparent.png

4 formats

blister · capsule · bead · in-situ

v19_02_no_cold_chain_transparent.png

No cold chain

the point of drying the reagent

v19_03_no_strict_moq_transparent.png

No strict MOQ

pricing improves with batch size

v19_04_three_four_weeks_transparent.png

3–4 weeks

from agreed requirements

v2_05_iso-13485-certified.png

ISO 13485

certified · FDA registered​

\ CAPABILITIES

Capabilities and technical specifications

Reagents are loaded on the line that builds the device — treatment before closure, reagent verified before it is sealed in. Your formulation stays yours; we build the storage around it.

Blister     LIQUID STORAGE

Liquid reagent sealed in the cartridge until the device calls for it — sized to the reagent volume and the release mechanism.

Blister

Formed cavity under a foil-laminate lid; burst at a designed weak point. Fixed dose, defined actuation stroke.

Capsule

Chamber inside the cartridge; pierced, crushed or opened on actuation. Larger volumes, release sequences a blister cannot give.

Liquid storage tube

Dedicated tube customized to the volume and to how the chip uses it.

Choose it when the device is still changing.

​

Lyophilization     DRIED STORAGE · NO COLD CHAIN

LYOPHILIZED BEAD

IN-SITU LYOPHILIZATION

How

Metered as a droplet, frozen as a sphere and dried — then each bead is checked and placed before closure

Dispensed into the device cavity as liquid and dried there, on the part

Equipment

Micro dispenser (droplet) · production lyophilizer · bead detection & placement

Micro dispenser (into the cavity) · production lyophilizer, device trays on the shelf

Approx. spec

Small, repeatable doses · dose fixed before drying  

Larger dried volumes · cake takes the cavity's shape  

Choose when

The cavity can accept and retain a bead; a bad unit must cost only a bead

A bead will not fit or reach, or would move in transit

Lyophilization · cavity treatment before loading

Sets how the reagent wets the cavity and reconstitutes — four methods, done on the line before dispensing

Sets how the reagent wets the cavity and reconstitutes — four methods, done on the line before dispensing

Full method and contact-angle detail: Surface treatment & functionalization →

Plasma

PLASMA SYSTEM

Activates the polymer surface — nothing added. Blanket treatment.

Hydrophilic < 10° · short-lived on PDMS (~15 min unless aged)

Wet chemical

WET CHEMICAL BENCH

Grafted or coupled chemistry — silanes, polymers, proteins. Selective within a part (in-well).

Hydrophilic or hydrophobic · durable

Spin coating

SPIN COATER

A spun polymer film over the surface, blanket or patterned.

​

​

Uniform film · durable

​

Thin film

CVD / PVD · PARYLENE COATER

A deposited film — metal, dielectric or Parylene; blanket, patterned or conformal.

Hydrophobic up to 110–150° · durable

Spec     Dose, residual-moisture and shelf-life figures are agreed per formulation at DFM.

STORAGE & LOADING

Customization

Cavity, blister, capsule and tube geometry designed to the reagent volume and to how the chip uses it

Blister lidding

Foil laminate — the moisture and oxygen barrier that usually limits the shelf-life claim

Contact materials

PP, PE, COC/COP — low extractables, low sorption of the analyte or label

Closure

PSA lamination or film seal; seal integrity through shipping, temperature cycling and actuation

Loading

Filling, bead detection and placement on our assembly lines, before device closure

DRYING & RELEASE

Cycle development

Freeze, primary-dry and secondary-dry cycle built around your formulation, below its collapse temperature

Residual moisture

Specified as a window, agreed at DFM — Karl Fischer or loss on drying

Release tests

Residual moisture · reconstitution time · activity against your assay

Packaging

Reagent tubes with optional desiccant; moisture-barrier packaging for loaded devices

Quality system

ISO 13485 certified · FDA registered

Fluid sac 04.jpg

\ PROCESS

Reagent loading process

Two ways to dry, chosen by the cavity; one closure and packaging line for everything.

  • Lyophilization — bead and in-situ

requirement.jpg

Requirements

Formulation, volume, release mechanism and acceptance criteria; drying cycle built below collapse temperature.

Below collapse temperature

Dispense.jfif

Dispense

Micro dispenser meters a droplet (bead) or fills the device cavity (in-situ).​

​

​​

​

Dose fixed here

​

Freeze & dry machine.webp

Freeze & dry

Frozen, then primary and secondary drying under vacuum to the residual-moisture target.​

​

​

Residual-moisture target

QC teat.jpg

Inspect (QC)

Every bead detected before placement; in-cavity cake checked; seals inspected; 100% vision.

​

Rejected, not sealed in

Bongding.jpg

Closure & sealing

PSA lamination or film seal, without the dried reagent seeing ambient humidity.

​

​

​

No ambient exposure

operator-tray-sealing-machine-01.jpg

Package & hand over

Tubes with optional desiccant, or barrier-packed devices; released to your stability study.

​

Foil laminate · desiccant

  • Blisters and capsules — fill and seal

The liquid formats take a shorter route, on the same line and in the same sequence relative to treatment and closure.

Material pair and requirement.jpg

Requirement

Reagent volume, release mechanism, actuation force and contact-material constraints.

​

​

Below collapse temperature

format.png

Format and geometry

Blister cavity or capsule chamber designed against the cartridge interface, not selected from a catalog.

Dose fixed before drying

sample.avif

Tooling and samples

Cavity tooled and sampled for fit, fill, seal and releas

​

​

​

Freezing rate sets pore structure

Fill and seal.png

Fill and seal

Dosed and sealed on the line, before device closure.

​

​

​

Residual-moisture target

operator-examining-chip-under-lamp-01.jpg

Integration

Assembled into the device and inspected.

​

​

​

 

Detected before placed

Lead time

3–4 weeks

from agreed requirements

​​

​

Cycle development

for a new formulation — ahead of the clock, quoted separately

No strict minimum

pricing improves with batch size

Two delivery forms

beads in reagent tubes, or loaded in the device

\ SHOWCASE

Showcase

Sample parts

The formats, photographed on parts made here.

reagent storage blisters.jpg

Reagent storage blisters

liquid held against a burstable foil seal, released by a designed actuation stroke

Reagent storage capsule.jpg

Reagent capsule

a sealed reservoir inside the cartridge, isolated from the device until the moment of use

Reagent lyophilization.jpg

Lyophilized beads

metered, dried and checked before the device is involved, then placed robotically, or shipped standalone in dedicated reagent tubes

Reagent storage tube.jpg

Reagent storage tube

Internal cavity geometry matches the reagent form for stable containment.

\ TESTIMONIALS

“

High-quality micro-patterned electrodes are a crucial part of SynVivo’s product portfolio. HiComp delivered them on schedule at a competitive price.

Jenna M Rosano

Senior Research Scientist, SynVivo, Huntsville, Alabama

FAQ

\ RELATED

Related services

hero.jpeg

The lines that load, seal and inspect the reagent — the same lines that build the device.

Bonding fixture press station

Sealing, PSA lamination and chamber closure without heat the reagent cannot take.

hero.jpeg

Wettability control applied in line, before reagent loading and the PSA closure.

Abstract White Waves

\ START HERE

TELL US ABOUT YOUR PROJECT

Reply within 2 business days.
NDA on request.

Project stage
Prototype
Pilot batch / process verification
Production
Quantity (per month at production)
Fewer than 20
20–200
200–2,000
More than 2,000
How did you hear about us?

By sending this, you agree that we may contact you about your inquiry. We do not add you to a mailing list.

Prefer to talk it through first? Book a design review →

bottom of page