window.onload = function() { if (typeof grecaptcha !== "undefined") { grecaptcha.render('recaptcha-container', { 'sitekey': '6LeALEkrAAAAAEDavc0NiMvKzg5nA-iqvVgzp63W' }); } else { console.error("Google reCAPTCHA failed to load."); } };
top of page
hero

Service \ Assembly & integration \ Surface treatment & functionalization

SURFACE TREATMENT & FUNCTIONALIZATION

Wettability control and biomolecule immobilization on plastics, glass, silicon, PDMS and particles.

MATERIAL

Plastics · glass · silicon · PDMS · particles

MINIMUM ORDER

No strict minimum

LEAD TIME

Quoted with the device

\ OVERVIEW

Surface treatment & functionalization

Surface functionalization modifies the wettability, adhesion and binding characteristics of a device surface to suit the assay. At microfluidic dimensions the surface-area-to-volume ratio is high enough that these properties decide whether a chip fills, whether cells attach, and whether an analyte is captured. We run hydrophilic and hydrophobic treatments, patterned wettability, automated microarray spotting and covalent biomolecule immobilization on polystyrene, PMMA, COC/COP, glass, silicon, PDMS and particles. The substrate decides the route as much as the target does: the same contact angle on polystyrene and on glass takes two routes.

surface treatment.png
v17_01_hydrophilic_angle_transparent.png

< 10°

hydrophilic contact angle

​

​

v17_02_hydrophobic_angle_transparent.png

110–150°

hydrophobic contact angle

 

​

v17_03_surface_functions_transparent.png

11 × 4

surface functions across four methods

​

​

v17_04_five_substrates_transparent.png

5

substrate classes — plastics, glass, silicon, PDMS, particles

v2_05_iso-13485-certified.png

ISO 13485

certified · FDA registered

​

​

\ CAPABILITIES

Capabilities and technical specifications

Reagent blisters and lyophilized reagent, and the surface treatment of the device itself — four methods under one roof. Contact angle is the acceptance criterion on every wettability treatment; the sequence relative to bonding is fixed at DFM.

Blister

THE PART

Sealed reagent blisters that store liquid reagent on the chip and release it on demand.

THE TREATMENT

The blister’s inner surface is treated on the same lines as the device, by the surface-treatment methods below.

THE SEQUENCE

Treated before reagent loading and sealing. Formats and storage: reagent storage →

Lyophilization

THE PART

Liquid reagent converted into freeze-dried beads for convenient, stable storage — or dried in situ, in the device cavity.

ON THE LINE

Each bead is detected before it is placed, so a missing or damaged bead is caught rather than sealed in.

THE SEQUENCE

After surface treatment, before closure — never left in ambient humidity. More: lyophilization →

Surface treatment

Four methods — how each works, then what each delivers. Contact angles are in Achievable wettability.

PLASMA

WET CHEMICAL

SPIN COATING

THIN FILM

Equipment

Plasma system

Wet chemical bench

Spin coater

CVD/PVD · parylene coater

How it works

Activates the polymer — nothing added

Grafted or coupled chemistry — silanes, polymers, proteins

A spun polymer film

A deposited film — metal, dielectric, Parylene

Patterning

Blanket

Selective within a part (in-well)

Blanket or patterned

Blanket, patterned or conformal

Durability

Shortest — PDMS reverts in ~15 min unless aged

Considerably more durable than plasma

 - 

 - 

What each method delivers

The matrix is our actual routing; the contact angle we commit to is stated per substrate in the quotation.

 

● offered by this method    ○ not the route we use for this function.

FUNCTION

PLASMA    

WET

SPIN

THIN FILM

TYPICAL APPLICATIONS

Hydrophilic

●

●

●

●

Capillary filling, rapid wetting, bubble reduction, sample loading

Hydrophobic

○

●

●

●

Hydrophobic valves, aqueous-phase isolation, droplet manipulation, digital microfluidics

Fluorophilic / oil-wetting

○

●

○

○

Water-in-oil droplets, digital PCR, single-cell droplets, double emulsions

Tissue culture

●

○

○

○

Adherent-cell culture, cell counting, cytotoxicity, organ-on-chip surfaces

ECM / bioactive

○

●

○

○

Collagen, fibronectin or laminin; cell migration, vascularization models

Ultra-low attachment

○

●

○

●

Spheroids, organoids, embryoid bodies, suspension culture

Low protein-binding

○

●

○

○

Immunoassays, protein detection, blood samples, biosensors

Biomolecule immobilization

○

●

○

●

Antibodies, DNA, aptamers, enzymes, peptides

Electrode surface

○

○

●

●

Electrochemical biosensors, impedance, MEA, EWOD, microheaters, DEP

Dielectric / passivation

○

○

●

●

EWOD dielectric layers, electrode insulation, capacitive sensing

Selective / patterned

○

○

●

●

Local wettability regions, cell patterning, multiplexed assay zones

Achievable wettability

CAPABILITY

DELIVERED RESULT

Hydrophilic

Contact angle below 10° — plasma, chemical grafting, silanization, CVD or polymer coupling

Below 60° on polystyrene and PMMA

Hydrophobic

Contact angle 110–150° — functional coatings, chemical modification or bioinspired micro-nano patterning

Above 105° on glass

Patterned

Hydrophilic and hydrophobic regions on one surface

Below 60° and above 105° on one silicon part

Immobilization

Covalent attachment of antibodies, DNA, aptamers, enzymes and peptides

Selective in-well functional groups with a hydrophobic exterior, on silicon

CAPABILITY

DELIVERED RESULT

Functionalize after bonding, not before.

Fusion and diffusion bonding run near the glass transition and destroy pre-applied surface chemistry. Either functionalize after the device is sealed, or close it with a lower-temperature method — solvent, adhesive or PSA. This is a design-stage decision.

hero

\ PROCESS

Treatment process

One route for both wettability targets — the function and the substrate set the method; patterning and immobilization are added where the design needs them.

Reflective Droplet in a Microfluidic Chip.png

Function and substrate

Target surface behavior, the substrate, and what it must survive — sterilization, storage, solvents.

​

​

​

Free DFM review

Stainless Vacuum Chamber with Purple Plasma.png

Method selection

Hydrophilic: 
plasma, grafting, silanization, CVD, polymer coupling. 


Hydrophobic: 
coatings, chemical modification, micro-nano patterning.

Bonding sequence fixed here

Hydrophilic surface treatment.avif

Treatment

Parameters developed on your actual substrate, then batch treatment with in-process checks.

​

​

< 10° hydrophilic · 110–150° hydrophobic

patterning.jfif

Patterning

Hydrophilic and hydrophobic regions on one surface; selective treatment inside a microwell.

​

​

​

​

Both regions on one part

Dispense.jfif

Immobilization & spotting

Antibodies, DNA, aptamers, enzymes or peptides; automated microarray spotting.

​

​

​

Position-recognized

Contact-angle QC.jfif

Contact-angle QC

Contact angle measured on treated parts; uniformity mapped where required.

​

​

​

​

Every lot

Lead time

3–4 weeks

from agreed requirements

​​

​

Cycle development

for a new formulation — ahead of the clock, quoted separately

No strict minimum

pricing improves with batch size

Two delivery forms

beads in reagent tubes, or loaded in the device

\ SHOWCASE

Showcase

Sample parts

Seven delivered treatments across six substrates and four treatment classes. The list spans rigid and soft substrates, plastics and inorganics, blanket and patterned application, wettability control and covalent chemistry.

#

TREATMENT

MATERIAL

PATTERNING

MEASURED

APPLICATION

1

Hydrophilic

Polystyrene

Non-patterned

Contact angle < 60°

Capillary-driven chips for cell staining

2

Hydrophilic

Polystyrene

Non-patterned

Contact angle < 60°

Rapid chamber filling and uniform cell distribution for cell counting

3

Hydrophobic

Glass

Non-patterned, uniform

Water contact angle > 105°

Through-glass via (TGV) devices

4

Hydrophilic + hydrophobic

Silicon

Patterned

< 60° / > 105°

Wettability-patterned array chips

5

Tissue culture

PS, COC/COP, glass

Non-patterned, uniform

    —

Cell-culture plates for adherent attachment and growth

6

Parylene coating

Magnetic particles

Conformal, uniform

    —

Passivation of magnetic particles — chemical stability and biocompatibility

7

Selective hydrophobic + immobilized functional groups

Silicon

Microwell array — hydrophobic outside, functional groups inside

    —

Microwell-array chips for sequencing: localized in-well capture, minimal non-specific binding

poct.jpg

CAPILLARY FILLING

Hydrophilic channels that fill by capillary action — pumpless cartridges that load a sample without an instrument.

​

organ-chip-perfusion-device-blue-01.jpg

TISSUE CULTURE · ULA

Tissue-culture surfaces for adherent growth; ultra-low-attachment surfaces for spheroids and organoids.

NGS.png

IN-WELL IMMOBILIZATION

Microwell arrays with capture chemistry inside the well and a hydrophobic exterior — localized capture, minimal non-specific binding.

Droplet microfluidics.JPG

FLUOROPHILIC

Oil-wetting channel walls for water-in-oil droplets, digital PCR, single-cell droplets and double emulsions.

\ TESTIMONIALS

“

High-quality micro-patterned electrodes are a crucial part of SynVivo’s product portfolio. HiComp delivered them on schedule at a competitive price.

Jenna M Rosano

Senior Research Scientist, SynVivo, Huntsville, Alabama

FAQ

\ RELATED

Related services

Bonding fixture press station

The sequence rule, and which bonding method preserves pre-applied surface chemistry.

robot-arm-molded-part-racks-01.jpg

Hydrophilic treatment applied in line, before reagent loading and closure.

Fluid sac 04.jpg

The chemistry that sits on the treated surface — beads, in-situ cakes, blisters and capsules.

Abstract White Waves

\ START HERE

TELL US ABOUT YOUR PROJECT

Reply within 2 business days.
NDA on request.

Project stage
Prototype
Pilot batch / process verification
Production
Quantity (per month at production)
Fewer than 20
20–200
200–2,000
More than 2,000
How did you hear about us?

By sending this, you agree that we may contact you about your inquiry. We do not add you to a mailing list.

Prefer to talk it through first? Book a design review →

bottom of page