Service \ Scale-up manufacturing \ Cleanroom injection molding
CLEANROOM INJECTION MOLDING
Precision and micro injection molding of medical devices and microfluidic devices in an ISO 7 cleanroom.
MATERIAL
COC · COP · PC · PMMA · PS · PP and more
MINIMUM ORDER
500 units
LEAD TIME
DFM in 1 week · T1 samples in 8–10 weeks
\ OVERVIEW
Cleanroom injection molding
Our injection molding for medical devices, diagnostics and microfluidics runs in a cleanroom that is ISO 7 / Class 10,000 throughout, with localized ISO 6, under an ISO 13485 quality system. The facility produces regulated product at millions of units per quarter. Two kinds of work share the same cleanroom. Precision medical molding covers housings, cartridges, surgical devices and consumables. Micro molding replicates sub-200 µm microfluidic channels and arrays, down to 2 µm, from molds we fabricate ourselves.


2 µm
finest moldable feature

±0.025 mm
standard dimensional tolerance

ISO 7
Class 10,000 cleanroom · localized ISO 6

6–8 weeks
tooling to first trial · one all-inclusive quotation

ISO 13485
certified · FDA registered
\ CAPABILITIES
Capabilities and technical specifications
The mold is made here — CNC to 20 µm, MEMS molds to 2 µm — with tooling to first trial in six to eight weeks and one all-inclusive quotation covering DFM, tooling, every trial round, OQ and PQ. ISO 7 across the molding floor, localized ISO 6 where needed, under ISO 13485.
Precision molding
FOR MEDICAL DEVICES
Typical devices
Housings, cartridges, surgical devices and consumables
Feature size
Above 200 µm; routine functional features ≥ 100 µm
Standard tolerance
±0.025 mm
Wall thickness
≥ 1.0 mm nominal; local walls and ribs to 0.6 mm, subject to flow length and DFM
Draft angle
1–2° on external walls
Tooling
Conventional precision molds
Development path
Direct to tooling from a released drawing
Metrology
CMM and optical microscopy
Special processes
Two-shot molding · silicone overmolding · insert molding
Micro molding
FOR MICROFLUIDIC DEVICES
Typical devices
Microfluidic chips, channels and arrays
Feature size
Below 200 µm; to 20 µm by high-speed CNC on selected low-aspect-ratio features after DFM; below 5 µm, to 2 µm under validated conditions, by MEMS mold
Critical tolerance
Down to ±0.002 mm, by feature size, material, mold design and measurement method
Aspect ratio
Routine 2:1; selected localized features to 3:1
Draft angle
0.5–1° on microfeatures; zero draft evaluated for short, shallow features
Surface roughness
Ra ≤ 0.02 µm polished; replicated channels Ra ≤ 0.20 µm
Tooling
High-speed CNC and proprietary MEMS mold fabrication
Development path
Prototyped in PDMS or CNC first; to tooling at design freeze
Metrology
White-light interferometry, profilometry, SEM and functional testing
Special processes
Micropillar and microwell array replication
Mold types
The mold sets the feature size. All four categories are designed and built in house; MEMS mold fabrication is described on the MEMS manufacturing page.
Single-cavity molds
Small-batch production and process testing
Multi-cavity molds
Large-scale production — the route for consumables such as PCR tubes and 96- and 384-well plates
Precision molds
Channel dimensions below 100 µm with strict surface-roughness requirements; generally high-precision CNC metal molds
MEMS-fabricated molds
Features below 5 µm, to 2 µm under validated conditions, by our proprietary MEMS mold fabrication

\ MATERIALS
Materials
Any injection-moldable thermoplastic; these six are the most requested.

Cyclic olefin copolymer
COC
LOW AUTOFLUORESCENCE
Microfluidic chips, optical and fluorescence detection, PCR consumables, microplates

Polycarbonate
PC
AUTOCLAVABLE, TOUGH
High-temperature or high-toughness parts; autoclaved devices

Cyclic olefin polymer
COP
LOW BIREFRINGENCE
Fluorescence and interferometric detection; optical-grade chips

Polystyrene
PS
CELL-CULTURE READY
Cell-culture consumables (tissue-culture treated); disposables

Acrylic
PMMA
BEST VISIBLE CLARITY
Manifolds, structural chips, cost-sensitive devices

Polypropylene
PP
CHEMICAL RESISTANT
Reagent contact and storage; fluid handling
Every resin here, and others — ABS, PEEK, PEI (Ultem), TPE — can be molded. Grade-level data: Materials guide.

\ PROCESS
Molding process
One route from released drawing to packaged part; every step in house.

DFM review
Product drawings, tolerances and acceptance criteria in; a written manufacturability report back — wall thickness, draft, gating, sink and weld-line risk.

Validation — OQ and PQ
Operational and performance qualification executed; written process and inspection plan agreed before release. IQ supported where the program requires it.

Mold design
Cavity count matched to volume — single-cavity for small batches and process testing, multi-cavity for scale — gate and runner layout, Moldflow filling analysis.

Production
Scheduled release under ISO 13485 in the ISO 7 cleanroom; programs running at millions of units per quarter.

Mold making
Conventional precision molds for medical components; high-speed CNC for features to 20 µm; proprietary MEMS mold fabrication below 5 µm.

Downstream processes
Bonding and sealing, surface functionalization, reagent storage and lyophilization, assembly and automation — in house, so the molded part never waits at a vendor boundary.

Trials — T0 to T1
First shots, dimensional verification and process-window development. Every trial round is inside the quotation.
Lead time
One all-inclusive quote — DFM, tooling, every trial round, OQ and PQ. NRE from $15,000.
Every route
1 week
DFM report
6–8 weeks
to first trial (T0) · industry 10–16
8–10 weeks
to T1 samples, after DFM
500 units
minimum order
\ QUALITY CONTROL
Quality control
Inspection requirements differ by product class. Both classes are supported in house.
↓ MEDICAL DEVICES
↓ MICROFLUIDIC DEVICES
Dimensional
White-light interferometry and stylus profilometry
CMM and optical microscopy
Surface and feature
SEM for replication fidelity and sub-micron feature verification
Optical microscopy
Functional
Burst and pressure, leak, tensile and pull-force, fluidic performance, protein adsorption
Dimensional and visual to drawing
Why it differs
Channels below 100 µm and surfaces at Ra 0.02 µm cannot be verified by CMM or caliper
Features are visible and measurable by contact methods
The cleanroom
Five views inside the cleanroom, from presses to packing.
\ SHOWCASE
Case studies and applications
Sample parts
24-well open-bottom plate for optical assays
Design-for-manufacturing optimization on a precision biological device with glass integration.

Draft-angle verification across the cavity before tool cutting.

Filling simulation confirming no short shot across the four-point gate layout.

REQUIREMENT
Customer specification
-
Open-bottom 24-well plate requiring thin optical interface compatibility
-
Risk of sink marks from thick wall regions
-
Tight dimensional control for glass bonding alignment
-
Need to ensure uniform filling without short shot
-
Weld lines and air traps expected due to multi-cavity geometry

ENGINEERING APPROACH
DFM output
-
Optimized wall thickness distribution to reduce shrinkage defects
-
Increased draft angles (1.5° → up to 5°) fo reliable demolding
-
Added locating features for glass alignment and assembly
-
Designed four-point gate cold-runner system for uniform filling
-
Verified moldability using Moldflow simulation: no short shot detected, controlled shrinkage (~0.74%), deformation <0.32 mm

AS MANUFACTURED
Production parameters
-
Material: GPPS (SECCO GPPS123 equivalent)
-
Part volume: 53 g
-
Cycle time: ~50 s
-
Mold: three-plate tooling (S136 steel)
-
Machine: 100-ton injection platform
-
Tool lifetime: 100,000 shots
-
Surface finish: Ra ≤ 0.02 µm achievable
-
Gate vestige controlled <0.25 mm
Other programs.
Precision microfluidic chips for single-cell sequencing, direct ELISA and flow cytometry; life-science consumables including 96- and 384-well plates and PCR tubes; over 500 customer projects completed.
Application
\ TESTIMONIALS
“
HiComp has manufactured the injection-molded components of our cartridges for four years, now at millions of units each quarter in their ISO-certified facilities. Consistency at that volume is difficult, and they have delivered it. They stay engaged through every design change.
Dr. Hong Tan
Founder and CEO, ET Healthcare, Palo Alto, California
FAQ