window.onload = function() { if (typeof grecaptcha !== "undefined") { grecaptcha.render('recaptcha-container', { 'sitekey': '6LeALEkrAAAAAEDavc0NiMvKzg5nA-iqvVgzp63W' }); } else { console.error("Google reCAPTCHA failed to load."); } };
top of page
3D .png

Service \ Design & prototype \ 3D printing

3D PRINTING

Two-photon and DLP micro 3D printing of molds, microneedles, scaffolds and fixtures, with prototypes in 48 hours.

MATERIAL

Photopolymer resins · nylon · polypropylene

MINIMUM ORDER

Quantity one — no tooling

LEAD TIME

Prototypes in 48 hours · devices in 3 days

\ OVERVIEW

3D printing

Our additive manufacturing for microfluidics runs on two light-based platforms: two-photon polymerization for sub-micron, genuinely three-dimensional structures, and DLP projection micro-printing for microscale detail at speed.

​

Most of what we print is something other than a channel — molds for PDMS chips, microneedle arrays, cell-culture scaffolds, optical and sensor interfaces, housings, fixtures and fluidic connectors. When the printed design is right, the same team carries it into CNC, soft lithography or injection molding.

new_submicron_transparent.png

Sub-micron

two-photon minimum feature

new_dlp_transparent.png

2 µm

DLP optical resolution · ±10 µm tolerance

new_48h_transparent.png

48 hours

standard prototype turnaround

v2_04_fast-delivery-5-10days.png

Qty 1

minimum order · no tooling

v2_05_iso-13485-certified.png

ISO 13485

certified · FDA registered

\ CAPABILITIES

Capabilities and technical specifications

The platform is chosen on the smallest feature that has to be right — two-photon for sub-micron detail, DLP for microscale parts at speed, powder bed for tough functional parts — with prototypes in 48 hours and no tooling. Prints are designed by microfluidics engineers for sealing, flow paths and assembly; PDMS molds get the anti-inhibition treatment as standard.

Platforms

TECHNOLOGY

SYSTEM

BUILD CAPACITY

RESOLUTION AND TOLERANCE

MATERIALS

Two-photon polymerization (2PP)

Nanoscribe Quantum X bio

50 × 50 mm

print area

Sub-micron minimum feature; written point by point at the focus of a 780 nm laser

Two-photon photoresins, including cell-culture and biocompatible grades

DLP projection micro-stereolithography

BMF S230

50 × 50 × 50 mm

2 µm optical resolution; ±10 µm dimensional tolerance

Microscale photopolymer resins — rigid, tough, high-temperature and biocompatible grades

LCD masked stereolithography

——

——

——

Standard and engineering photopolymer resins — rigid, tough, high-temperature, castable

Also available

Powder-bed polymer

Nylon (polyamide) and polypropylene. No support structures required; used for functional housings, frames, jigs and chemically resistant parts

Post-processing

Wash and post-cure, support removal, surface treatment, silanization and conformal coating on molds

Downstream

Casting into PDMS, bonding, assembly and transfer to CNC or injection molding, all in house

Resolution and tolerance are not the same number.

A 2 µm optical resolution describes the smallest detail the projector can define; ±10 µm describes how close the finished part is to the CAD dimension. A microneedle tip is a resolution question. A part that has to seal against a mating face is a tolerance question — and the difference matters when quoting.

Larger than the build volume?

Parts are printed in sections and assembled, or made by CNC instead — which is often the better answer above this size anyway.

Equipment

The two-photon and DLP printers named in the platform table above.

Nanoscribe Quantum X bio.avif

Nanoscribe Quantum X bio

Principle

A 780 nm laser polymerizes a light-sensitive resin only at its focus, writing sub-micron 3D structures

Applications

Superlenses and metasurfaces, microneedles, cell-culture scaffolds, microfluidic molds

Maximum build area

50 × 50 mm​​

​

BMF S230.avif

BMF S230

Principle

Digital light projection cures each layer as one image, for high-resolution, rapid prototyping of microscale structures

Applications

Microneedle arrays, PDMS chip molds, microchannel test structures

​

Maximum build volume

50 × 50 × 50 mm

​

\ MATERIALS

Materials

Photopolymers on the two light-based platforms; nylon and polypropylene where a part has to take load or resist solvent. Characteristics are family-level; we confirm the grade at DFM against what the part will touch.

Microscale photopolymer resins

Microscale photopolymer resins

On DLP — BMF S230

CHARACTERISTICS

smooth surface, high dimensional accuracy, good toughness, low water absorption

TYPICAL USE

PDMS chip molds, microneedle arrays, microchannel test structures, optical and sensor interfaces, fixtures

Two-photon photoresins

Two-photon photoresins

On 2PP — Nanoscribe Quantum X bio

CHARACTERISTICS

written point by point at sub-micron resolution

​

​

TYPICAL USE

cell-culture scaffolds, fine microneedle tips, micro-lens arrays and metasurfaces, high-resolution molds

Nylon - 3D printing material

Nylon (polyamide) 

On powder bed

CHARACTERISTICS

high strength and toughness, high chemical resistance

TYPICAL USE

functional housings, cartridge frames, jigs and fixtures that see load

​

​​

​

​​​

Polypropylene - 3D printing materials

Polypropylene

On powder bed

CHARACTERISTICS

high toughness, very low water absorption, high chemical resistance, electrical insulation

TYPICAL USE

chemically demanding functional parts and fluidic components

​

​

​

​

Printed resin can stop PDMS from curing.

Residual photoinitiator and unreacted amine species at the resin surface poison the platinum cure of Sylgard 184, so the PDMS in contact with the mold stays tacky. The fix is a controlled post-cure and a barrier treatment (silanization or parylene) before first casting — standard on molds we know are for PDMS, so tell us what the print is for.

Closed printed channels are difficult to clear, and difficult to trust.

Uncured resin trapped inside a printed channel is hard to remove and continues to leach. For anything with cells, reagent or an optical read, print the channel open and bond a lid — we design for that at DFM and do the bonding here.

3D printing vs. CNC micro milling vs. soft lithography vs. injection molding

Printing earns its place where geometry, speed or feature size is the constraint, or where the part is a mold, fixture, scaffold or a design that will be remade in a production process.

ASPECT

3D PRINTING

CNC MICRO MILLING

SU-8 SOFT LITHOGRAPHY

INJECTION MOLDING

Tooling cost

None

None

Master required

Production mold

True 3D geometry

Yes — the main reason to choose it

Partial — multi-axis, layered plates

No — planar features only

Limited by draw direction

Minimum feature

Sub-micron (2PP); ~2 µm (DLP)

~100 µm

~5 µm

> 500 µm general features; 10–200 µm replicated channels

Turnaround

48 hours

5–10 days

1–2 weeks

8–10 weeks to T1

Material realism

Photopolymer or powder polymer — not a production thermoplastic

Production thermoplastic

Production PDMS

Production thermoplastic

Sensible quantity

1–200

1–500

20–5,000

500 upward

The honest limit: a printed part is rarely the product.

Photopolymers are not the resins a device ships in. COC, COP and PC are not printable in any process we would recommend for a fluidic device — those go to CNC micro milling for prototypes and injection molding for volume. Every substrate, grade by grade, is in the Materials guide.

hero.jpeg

\ PROCESS

Printing process

One route from CAD to part; the platform is chosen on the smallest feature.

DFM.png

Design and DFM

CAD reviewed against the platform: minimum feature, write strategy or layer orientation, supports, which faces have to seal — and, if the part is a mold, draw direction and release. Sub-micron detail such as needle tips, scaffold struts and optical structures routes to two-photon; microscale parts to DLP.

Free DFM review

Layer-by-layer projection.webp

Printing

Two-photon: a 780 nm laser polymerizes the resin only at its focus, writing the structure voxel by voxel in three dimensions. DLP: each layer is projected as a single image and cured at once, so build time scales with height rather than detail.

Sub-micron · 50 × 50 mm (2PP) · 2 µm, ±10 µm (DLP)

Wash and post-cure_edited.jpg

Wash and post-cure

Uncured resin removed and the part cured to completion. For PDMS molds this stage is extended, because incomplete cure is what causes cure inhibition later.

​

​

​

​

Extended cure for PDMS molds

Support removal and surface treatment.webp

Support removal and surface treatment

Supports removed. Where the print is a mold: silanization or a conformal parylene coating against cure inhibition and for release. Functionalization on parts that will contact cells or reagent.

​​

​

Silanization · parylene

operator-digital-microscope-chip-01.jpg

Inspection

Dimensional check by optical microscopy and profilometry against the drawing; critical microfeatures — needle tips, channel cross-sections, lens profiles — inspected individually; surfaces checked for witness marks, layer stepping and residual resin.

Critical features inspected individually

cnc-milling-machine-interior-01.jpg

What happens next

Cast into PDMS, bonded with a lid, assembled, or transferred to CNC or injection molding — all in house, with the transfer implications flagged at DFM rather than discovered at tooling.

​

​

48-hour prototype · 3-day device

Lead time

48 hours

standard prototype from a clean CAD file

3 days

custom device — printed, treated, assembled

Quantity one

no tooling, nothing to amortize

1–200 pieces

sensible range; above it, CNC or molding

\ SHOWCASE

Showcase

Applications

Needle arrays Microneedles.png

NEEDLE ARRAYS

Tip geometry set by two-photon resolution; arrays and their molds printed for transdermal delivery and sampling.

hand-holding-perfusion-chip-black-01.jpg

CHIP MOLDS

PDMS chip molds with the three-dimensional geometry SU-8 cannot form, treated against cure inhibition and cast here.

cell culture.png

SCAFFOLDS

Scaffolds that give a culture its three-dimensional structure, written in cell-culture grade photoresins.

3D .png

TRANSDERMAL

Microneedle arrays and delivery-device components prototyped in 48 hours, then moved to molding when the design is frozen.

\ TESTIMONIALS

“

Working with HiComp has allowed us to increase both the quality and the quantity of the organ-on-a-chip experiments that we conduct. Utilizing HiComp’s outstanding service and products has both made our lives easier and our research better.

John R. Minnick

NeuroAI and ML Researcher, University of California, Santa Cruz

FAQ

Abstract White Waves

\ START HERE

TELL US ABOUT YOUR PROJECT

Reply within 2 business days.
NDA on request.

Project stage
Prototype
Pilot batch / process verification
Production
Quantity (per month at production)
Fewer than 20
20–200
200–2,000
More than 2,000
How did you hear about us?

By sending this, you agree that we may contact you about your inquiry. We do not add you to a mailing list.

Prefer to talk it through first? Book a design review →

bottom of page