Service \ Design & prototype \ 3D printing
3D PRINTING
Two-photon and DLP micro 3D printing of molds, microneedles, scaffolds and fixtures, with prototypes in 48 hours.
MATERIAL
Photopolymer resins · nylon · polypropylene
MINIMUM ORDER
Quantity one — no tooling
LEAD TIME
Prototypes in 48 hours · devices in 3 days
\ OVERVIEW
3D printing
Our additive manufacturing for microfluidics runs on two light-based platforms: two-photon polymerization for sub-micron, genuinely three-dimensional structures, and DLP projection micro-printing for microscale detail at speed.
Most of what we print is something other than a channel — molds for PDMS chips, microneedle arrays, cell-culture scaffolds, optical and sensor interfaces, housings, fixtures and fluidic connectors. When the printed design is right, the same team carries it into CNC, soft lithography or injection molding.


Sub-micron
two-photon minimum feature

2 µm
DLP optical resolution · ±10 µm tolerance

48 hours
standard prototype turnaround

Qty 1
minimum order · no tooling

ISO 13485
certified · FDA registered
\ CAPABILITIES
Capabilities and technical specifications
The platform is chosen on the smallest feature that has to be right — two-photon for sub-micron detail, DLP for microscale parts at speed, powder bed for tough functional parts — with prototypes in 48 hours and no tooling. Prints are designed by microfluidics engineers for sealing, flow paths and assembly; PDMS molds get the anti-inhibition treatment as standard.
Platforms
TECHNOLOGY
SYSTEM
BUILD CAPACITY
RESOLUTION AND TOLERANCE
MATERIALS
Two-photon polymerization (2PP)
Nanoscribe Quantum X bio
50 × 50 mm
print area
Sub-micron minimum feature; written point by point at the focus of a 780 nm laser
Two-photon photoresins, including cell-culture and biocompatible grades
DLP projection micro-stereolithography
BMF S230
50 × 50 × 50 mm
2 µm optical resolution; ±10 µm dimensional tolerance
Microscale photopolymer resins — rigid, tough, high-temperature and biocompatible grades
LCD masked stereolithography
——
——
——
Standard and engineering photopolymer resins — rigid, tough, high-temperature, castable
Also available
Powder-bed polymer
Nylon (polyamide) and polypropylene. No support structures required; used for functional housings, frames, jigs and chemically resistant parts
Post-processing
Wash and post-cure, support removal, surface treatment, silanization and conformal coating on molds
Downstream
Casting into PDMS, bonding, assembly and transfer to CNC or injection molding, all in house
Resolution and tolerance are not the same number.
A 2 µm optical resolution describes the smallest detail the projector can define; ±10 µm describes how close the finished part is to the CAD dimension. A microneedle tip is a resolution question. A part that has to seal against a mating face is a tolerance question — and the difference matters when quoting.
Larger than the build volume?
Parts are printed in sections and assembled, or made by CNC instead — which is often the better answer above this size anyway.
Equipment
The two-photon and DLP printers named in the platform table above.

Nanoscribe Quantum X bio
Principle
A 780 nm laser polymerizes a light-sensitive resin only at its focus, writing sub-micron 3D structures
Applications
Superlenses and metasurfaces, microneedles, cell-culture scaffolds, microfluidic molds
Maximum build area
50 × 50 mm

BMF S230
Principle
Digital light projection cures each layer as one image, for high-resolution, rapid prototyping of microscale structures
Applications
Microneedle arrays, PDMS chip molds, microchannel test structures
Maximum build volume
50 × 50 × 50 mm
\ MATERIALS
Materials
Photopolymers on the two light-based platforms; nylon and polypropylene where a part has to take load or resist solvent. Characteristics are family-level; we confirm the grade at DFM against what the part will touch.

Microscale photopolymer resins
On DLP — BMF S230
CHARACTERISTICS
smooth surface, high dimensional accuracy, good toughness, low water absorption
TYPICAL USE
PDMS chip molds, microneedle arrays, microchannel test structures, optical and sensor interfaces, fixtures

Two-photon photoresins
On 2PP — Nanoscribe Quantum X bio
CHARACTERISTICS
written point by point at sub-micron resolution
TYPICAL USE
cell-culture scaffolds, fine microneedle tips, micro-lens arrays and metasurfaces, high-resolution molds

Nylon (polyamide)
On powder bed
CHARACTERISTICS
high strength and toughness, high chemical resistance
TYPICAL USE
functional housings, cartridge frames, jigs and fixtures that see load

Polypropylene
On powder bed
CHARACTERISTICS
high toughness, very low water absorption, high chemical resistance, electrical insulation
TYPICAL USE
chemically demanding functional parts and fluidic components
Printed resin can stop PDMS from curing.
Residual photoinitiator and unreacted amine species at the resin surface poison the platinum cure of Sylgard 184, so the PDMS in contact with the mold stays tacky. The fix is a controlled post-cure and a barrier treatment (silanization or parylene) before first casting — standard on molds we know are for PDMS, so tell us what the print is for.
Closed printed channels are difficult to clear, and difficult to trust.
Uncured resin trapped inside a printed channel is hard to remove and continues to leach. For anything with cells, reagent or an optical read, print the channel open and bond a lid — we design for that at DFM and do the bonding here.
3D printing vs. CNC micro milling vs. soft lithography vs. injection molding
Printing earns its place where geometry, speed or feature size is the constraint, or where the part is a mold, fixture, scaffold or a design that will be remade in a production process.
ASPECT
3D PRINTING
CNC MICRO MILLING
SU-8 SOFT LITHOGRAPHY
INJECTION MOLDING
Tooling cost
None
None
Master required
Production mold
True 3D geometry
Yes — the main reason to choose it
Partial — multi-axis, layered plates
No — planar features only
Limited by draw direction
Minimum feature
Sub-micron (2PP); ~2 µm (DLP)
~100 µm
~5 µm
> 500 µm general features; 10–200 µm replicated channels
Turnaround
48 hours
5–10 days
1–2 weeks
8–10 weeks to T1
Material realism
Photopolymer or powder polymer — not a production thermoplastic
Production thermoplastic
Production PDMS
Production thermoplastic
Sensible quantity
1–200
1–500
20–5,000
500 upward
The honest limit: a printed part is rarely the product.
Photopolymers are not the resins a device ships in. COC, COP and PC are not printable in any process we would recommend for a fluidic device — those go to CNC micro milling for prototypes and injection molding for volume. Every substrate, grade by grade, is in the Materials guide.

\ PROCESS
Printing process
One route from CAD to part; the platform is chosen on the smallest feature.

Design and DFM
CAD reviewed against the platform: minimum feature, write strategy or layer orientation, supports, which faces have to seal — and, if the part is a mold, draw direction and release. Sub-micron detail such as needle tips, scaffold struts and optical structures routes to two-photon; microscale parts to DLP.
Free DFM review

Printing
Two-photon: a 780 nm laser polymerizes the resin only at its focus, writing the structure voxel by voxel in three dimensions. DLP: each layer is projected as a single image and cured at once, so build time scales with height rather than detail.
Sub-micron · 50 × 50 mm (2PP) · 2 µm, ±10 µm (DLP)

Wash and post-cure
Uncured resin removed and the part cured to completion. For PDMS molds this stage is extended, because incomplete cure is what causes cure inhibition later.
Extended cure for PDMS molds

Support removal and surface treatment
Supports removed. Where the print is a mold: silanization or a conformal parylene coating against cure inhibition and for release. Functionalization on parts that will contact cells or reagent.
Silanization · parylene

Inspection
Dimensional check by optical microscopy and profilometry against the drawing; critical microfeatures — needle tips, channel cross-sections, lens profiles — inspected individually; surfaces checked for witness marks, layer stepping and residual resin.
Critical features inspected individually

What happens next
Cast into PDMS, bonded with a lid, assembled, or transferred to CNC or injection molding — all in house, with the transfer implications flagged at DFM rather than discovered at tooling.
48-hour prototype · 3-day device
Lead time
48 hours
standard prototype from a clean CAD file
3 days
custom device — printed, treated, assembled
Quantity one
no tooling, nothing to amortize
1–200 pieces
sensible range; above it, CNC or molding
\ SHOWCASE
Showcase
Applications
NEEDLE ARRAYS
Tip geometry set by two-photon resolution; arrays and their molds printed for transdermal delivery and sampling.
CHIP MOLDS
PDMS chip molds with the three-dimensional geometry SU-8 cannot form, treated against cure inhibition and cast here.
SCAFFOLDS
Scaffolds that give a culture its three-dimensional structure, written in cell-culture grade photoresins.
TRANSDERMAL
Microneedle arrays and delivery-device components prototyped in 48 hours, then moved to molding when the design is frozen.
\ TESTIMONIALS
“
Working with HiComp has allowed us to increase both the quality and the quantity of the organ-on-a-chip experiments that we conduct. Utilizing HiComp’s outstanding service and products has both made our lives easier and our research better.
John R. Minnick
NeuroAI and ML Researcher, University of California, Santa Cruz